Ventilated active façades to reduce heating demand in office buildings. The case of Spain
DOI:
https://doi.org/10.3989/ic.11.099Keywords:
Energy efficiency, heating strategies, ventilated active façade, office buildingsAbstract
This paper analyses the energy efficiency of a Ventilated Active Façade –VAF– applied to office buildings in Spain to reduce heating demand. This façade system consists of an outer layer element of 2 mm galvanized steel panels and a 3 cm air cavity where the ventilation air is preheated in winter and exhausted in summer. After defining 8 typical office typologies in Spain, 192 study cases are obtained where different parameters like the percentage of glass in façade, the orientation and the climatic zone of the buildings are considered. The energy demand of all these study cases is obtained using the official simulation tool of the Spanish Technical Building Regulation – CTE called LIDER. The results, in terms of reduction of heating demand, are presented in comparison with the minimum energetic requirements of CTE.
Downloads
References
(1) Irulegi, O.: Energy efficiency of Ventilated Active Façades applied to office buildings in Spain, PhD Thesis, Universidad del País Vasco EHU UPV, 2011
(2) Arons, D.M.M.; Glicksman, L.R.: “Double Skin, Airflow Facades: will the Popular European Model work in the USA?”. Proceedings of ICBEST 2001, International Conference on Building Envelope Systems and Technologies 1, pp 203- 207, Ottawa, 2001.
(3) Harrison, K.; Meyer-Boake, T.: The Tectonics of the Environmental Skin, University of Waterloo, School of Architecture, 2003. Disponible en http://www.fes.uwaterloo.ca/architecture/faculty _projects/terri/ds/double.pdf
(4) Uuttu, S.: Study of Current Structures in Double-Skin Facades. MSc thesis in Structural Engineering and Building Physics, Department of Civil and Environmental Engineering, Helsinki University of Technology (HUT), 2001. Disponible en http://www.hut.fi/Units/Civil/Steel/SINI2.PDF
(5) Saelens, D.: Energy Performance Assessments of Single Storey Multiple-Skin Facades. PhD thesis, Laboratory for Building Physics, Department of Civil Engineering, Catholic University of Leuven, 2002. Disponible en http://envelopes.cdi.harvard.edu/envelopes/content/resources/pdf/case_studies/PhD_Dirk_Saelens.pdf
(6) Belgian Building Research Institute – BBRI. Source book for a better understanding of conceptual and operational aspects of active facades, Bruselas, 2002. Disponible en http://www.bbri.be/activefacades/index2.htm
(7) Poirazis, H.: Single and double skin. Glazed office buildings. Analyses of energy use and indoor climate. PhD Thesis, Division of Energy and Building Design, Department of Architecture and Built Environment, Lund University, Faculty of Engineering, Lund, 2008.
(8) Ruiz-Pardo, A.: Ahorro energético mediante el uso de elementos de doble envolvente transparente-opaco. PhD Thesis, University of Seville, Sevilla, 2008.
(9) Commission of the European Communities. GREEN PAPER on Energy Efficiency - or Doing More With Less, Bruselas, 2005.
(10) Ebbert, T.: RE-FACE: Refurbishment Strategies for the Technical Improvement of Office Façades, PhD Thesis, Technische Universiteit Delft, Pubblished by Thiemo Ebbert, Bochum, 2010.
(11) Ruiz-Pardo, A.: “Simulation Model for Some Types of Double Envelope Elements”. The International Journal of Ventilation 9 No 3, 2010.
(12) Ministerio de Industria, Turismo y Comercio. Gobierno de España. Globalización y deslocalización. Importancia y efectos para la industria española. División de Información, Documentación y Publicaciones, Centro de Publicaciones, Madrid, 2008.
(13) IDAE, Dpto. Planificación y Estudios, Segurado de Arriba, P. y García Montes, J.P. Evolución del consumo y de la intensidad energética en España, Análisis Global y Sectorial de la evolución del consumo y de la intensidad energética en España. Comparación a nivel europeo, 2008.
(14) Coyne, R.; Snodgrass, R.: "Metaphors in the design studio". Journal of Architectural Education 48 2, pp. 113–125, 1994. http://dx.doi.org/10.2307/1425318
(15) Orosa, J.A.; Oliveira, A.C.: "Energy saving with passive climate control methods in Spanish office buildings". Energy and Buildings 41, pp.823-828, 2009. http://dx.doi.org/10.1016/j.enbuild.2009.03.004
(16) Jpedicke, J.: Bu.ro und Verwaltungsbauten. Internationale Beispiele. Informationsdaten in Bild und Text, Karl Krämer Verlag, Stuttgart, 1975.
(17) Manasseh, L.; Cunliffe. R.: Office Buildings. B.T. Bastford Ltd, Londres, 1962.
(18) Hascher, R.; Jeska, S.; Klauck, B.: Entwurf Bu.robau, Bikhäuser- Verlag Architektur, Basilea/Berlin/Boston, 1985.
(19) Arquitectura Viva. nº70 -126, Arquitectura Viva SL, Madrid.
(20) Tectónica. nº 11-28, ATC Ediciones, Madrid.
(21) Detail. nº1(2002) – n.º1 (2010), Institut fu.r internationale Architektur-Dokumentation GmbH + Co. KG, Múnich
(22) EnergyPlus Weather data on the website: http://apps1.eere.energy.gov
(23) Sanchez de la Flor, F.J.; Alvarez, S.; Molina, J.L.; Gonzalez, R.: "Climatic zoning and its application to Spanish building energy performance regulations". Energy and Buildings 40, pp.1984-1990, 2008. http://dx.doi.org/10.1016/j.enbuild.2008.05.006
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2012 Consejo Superior de Investigaciones Científicas (CSIC)

This work is licensed under a Creative Commons Attribution 4.0 International License.
© CSIC. Manuscripts published in both the print and online versions of this journal are the property of the Consejo Superior de Investigaciones Científicas, and quoting this source is a requirement for any partial or full reproduction.
All contents of this electronic edition, except where otherwise noted, are distributed under a Creative Commons Attribution 4.0 International (CC BY 4.0) licence. You may read the basic information and the legal text of the licence. The indication of the CC BY 4.0 licence must be expressly stated in this way when necessary.
Self-archiving in repositories, personal webpages or similar, of any version other than the final version of the work produced by the publisher, is not allowed.