Infrared thermography applied to historical domes: identification and analysis of building systems

Authors

  • J. C. Pérez-Sánchez Universidad de Alicante
  • B. Piedecausa-García Universidad de Alicante

DOI:

https://doi.org/10.3989/ic.14.133

Keywords:

Infrared thermography, dome, constructive examination, non-destructive method, historical buildings, heritage conservation

Abstract


The specific use of infrared thermography as a non-destructive technique allows the study of constructive systems in historic buildings (characterization of materials, construction layers and identification of original / restored elements). Thus, a practical application is shown in temples built between the late seventeenth and the early nineteenth century in the province of Alicante, where complementarity of thermographic images of 140 domes is analysed (along with data collected in situ, original drawings and draw up plans) as a research tool in analysis phases prior to a restoration. In conclusion, research shows how thermography is applicable to the study of different aspects such as the recognition of materials used (90.71 % solid brick, 6.43 % hollow brick and 2.86 % stone), thickness variations (75.71 % pointed shape, 17.86 % hemispherical shape and 6.43 % low shape), characterization of cracks / fissures (conservation conditions) and identification of original (96.43 %) o restored domes (3.57 %).

Downloads

Download data is not yet available.

References

(1) Capitulos y Condiciones del arrendamiento de la obra de la torre. Documentos de la Iglesia de Catral, G29. (1744). Catral: Archivo Parroquial de los Santos Juanes de Catral.

(2) AENOR. (1987). UNE-EN-ISO 7345 Aislamiento térmico. Magnitudes físicas y definiciones. Madrid: Asociación Española de Normalización y Certificación (AENOR).

(3) Infrared Training Center. (2003). Manual Curso Termografía nivel I. Madrid: Infrared Training Center, Alava Ingenieros.

(4) AENOR. (2007). UNE-EN ISO 6946 Componentes y elementos para la edificación. Resistencia térmica y transmitancia térmica. Método de cálculo. Madrid: Asociación Española de Normalización y Certificación (AENOR).

(5) González Fernández, D. A. (2006). Contribuciones a las técnicas no destructivas para evaluación y prueba de procesos y materiales basadas en radiaciones infrarrojas (Tesis doctoral). Santander: Escuela Técnica Superior de Ingenieros Industriales y de Telecomunicación.

(6) Balaras, C. A., Argiriou, A. A. (2002). Infrared Thermography for Building Diagnostics. Elsevier Energy and Buildings, 34(2): 171-183. http://dx.doi.org/10.1016/S0378-7788(01)00105-0

(7) Barreira, E., de Freitas, V. (2007). Evaluation of building materials using infrared thermography. Construction and Building Materials, 21(1): 218-224. http://dx.doi.org/10.1016/j.conbuildmat.2005.06.049

(8) Ca-as Guerrero, I., Martín Oca-a, S., González Requena, I. (2003). Aplicabilidad de la termografía para la inspección de los edificios rurales: caso de una comarca española. Informes de la Construcción, 55(488): 21-28.

(9) García Jara, F. (2008). Las cúpulas de la arquitectura religiosa de la provincia de Alicante: del renacimiento al siglo XIX (Tesis doctoral). Valencia: Universidad Politécnica de Valencia. PMid:17868190

(10) Expediente sobre los planes respectivos a la parroquial de Monóvar (1769). Monóvar: Archivo Parroquial de San Juan Bautista de Monóvar.

(11) Restauración de la cúpula de la iglesia de Santa María Magdalena. (2009). Tibi: Archivo Municipal de Tibi.

(12) Pérez Jiménez, R., Capell Bore, L. (1987). Proyecto de restauración y consolidación de la iglesia de San Pedro en Pinoso. Primera Fase. Proyecto de arquitectura.

(13) Pérez Sánchez, J. C., Piedecausa García, B. (2015). Cúpulas de crucero en templos de la provincia de Alicante (s.xvii-xix): construcción y geometría. Informes de la Construcción, 67(538): e077. http://dx.doi.org/10.3989/ic.13.176

(14) Fornés y Gurrea, M. (1841). Observaciones sobre la práctica del arte de edificar. Valencia: Imprenta de Cabrerizo.

(15) Documentación de la Restauración de la iglesia. (1990). Archivo Parroquial de San Juan Bautista de Cox.

(16) García Navarro, J. J., Navarro Mallebrera, R., Serrano Bru, A. (2009). Las huellas del tiempo, construcción y restauración de la Basílica de Santa María. Elche: Gráficas Estilo. PMCid:PMC2691787

Published

2016-03-30

How to Cite

Pérez-Sánchez, J. C., & Piedecausa-García, B. (2016). Infrared thermography applied to historical domes: identification and analysis of building systems. Informes De La Construcción, 68(541), e129. https://doi.org/10.3989/ic.14.133

Issue

Section

Research Articles