Test cell data-based predictive modelling to determine HVAC energy consumption for three façade solutions in Madrid

Authors

DOI:

https://doi.org/10.3989/id.54794

Keywords:

predictive modelling, energy efficiency, façades, test cells, energy retrofitting

Abstract


This study aims to narrow the gap between predicted and actual energy performance in buildings. Predictive models were established that relate the electric consumption by HVAC systems to maintain certain indoor environmental conditions in variable weather to the type of façade. The models were developed using data gathered from test cells with adiabatic envelopes on all but the façade to be tested. Three façade types were studied. The first, the standard solution, consisted in a double wythe brick wall with an intermediate air space, the configuration most commonly deployed in multi-family dwellings built in Spain between 1940 and 1980 (prior to the enactment of the first building codes that limited overall energy demand in buildings). The other two were retrofits frequently found in such buildings: ventilated façades and ETICS (external thermal insulation composite systems). Two predictive models were designed for each type of façade, one for summer and the other for winter. The linear regression equations and the main statistical parameters are reported.

Downloads

Download data is not yet available.

References

(1) Ministerio de Obras Públicas y Urbanismo, Gobierno de España. NBE CT-79. Norma Básica de la Edificación: Sobre condiciones térmicas en los edificios (1979).

(2) León, A.L., Muñoz, S., León, J., Bustamante, P. (2010). Monitoring environmental and energy variables in the construction of subsidized housing: Cros-Pirotecnia building in Sevilla. Informes de la Construcción, 62(519): 67-82. https://doi.org/10.3989/ic.09.045

(3) Santamouris, M., Alevizos, S.M., Aslanoglou, L., Mantzios, D., Sarelli, I., Karatasou, S., Cartalis, K., Paravantis, J.A. (2014). Freezing the poor-Indoor environmental quality in low and very low income households during the winter period in Athens. Energy and Buildings, 70: 61-70, https://doi.org/10.1016/j.enbuild.2013.11.074

(4) Terés-Zubiaga, J., Martín, K., Erkoreka, A., Sala, J.M. (2013). Field assessment of thermal behaviour of social housing apartments in Bilbao, Northern Spain. Energy and Buildings, 67: 118-135. https://doi.org/10.1016/j.enbuild.2013.07.061

(5) Crawley DB, Hand JW, Kummert M, Griffith BT (2008). Contrasting the capabilities of building energy performance simulation programs. Building and Environment, 43 (4): 661-673. https://doi.org/10.1016/j.buildenv.2006.10.027

(6) Qin, M., Yang, J. (2016). Evaluation of different thermal models in EnergyPlus for calculating moisture effects on building energy consumption in different climate conditions. Building. Simulation 9 (1): 15-25. https://doi.org/10.1007/s12273-015-0263-2

(7) Sunikka-Blank, M., Galvin, R. (2012). Introducing the prebound effect: the gap between performance and actual energy consumption. Building Research and Information, 40 (3): 260-273. https://doi.org/10.1080/09613218.2012.690952

(8) Sendra, J.J., Domínguez, S., Bustamante, P., León, A.L. (2013). Energy intervention in the residential sector in the south of Spain: Current challenges. Informes de la Construcción, 65(532): 457-464. https://doi.org/10.3989/ic.13.074

(9) Blázquez, T., Suárez, R., Sendra, J.J. (2015). Towards a calibration of building energy models: A case study from the Spanish housing stock in the Mediterranean climate. Informes de la Construcción, 67(540): e128. https://doi.org/10.3989/ic.15.081

(10) Kim, K.H., Haberl, J.S. (2016). Development of a home energy audit methodology for determining energy and cost efficient measures using an easy-to-use simulation: Test results from single-family houses in Texas, USA. Building Simulation, 9(6): 617-628, https://doi.org/10.1007/s12273-016-0299-y

(11) Wouters, P., Vandeale, L., Voit, P., Fisch, N. (1993). The use of outdoor test cells for thermal and solar building research within the PASSYS Project. Building and Environment, 28 (2): 107-113. https://doi.org/10.1016/0360-1323(93)90044-4

(12) Strachan, P.A., Vandaele, L. (2008). Case studies of outdoor testing and analysis of building components. Building and Environment, 43 (2): 129-142. https://doi.org/10.1016/j.buildenv.2006.10.043

(13) Strachan, P.A. (2008). "Simulation support for performance assessment of building components". Building and Environment, 43 (2): 228-236. https://doi.org/10.1016/j.buildenv.2006.10.051

(14) Strachan, P.A., Baker, P.A. (2008). Outdoor testing, analysis and modelling of building components. Building and Environment, 43 (2): 127-128. https://doi.org/10.1016/j.buildenv.2006.10.008

(15) Leal, V., Maldonado, E. (2008). The role of PASLINK test cell in the modelling and integrated simulation of an innovative window. Building and Environment, 43 (2): 217-227. https://doi.org/10.1016/j.buildenv.2006.10.025

(16) Piccolo, A. (2010). Thermal performance of an electrochromic smart window tested in an environmental test cell. Energy and Buildings, 42: 1409-1417. https://doi.org/10.1016/j.enbuild.2010.03.010

(17) Carlos, J.S., Corvacho, H., Silva, P.D., Castro-Gómes, J.P (2011). Modelling and simulation of a ventilated double window. Applied Thermal Engineering, 31 (1): 93-102. https://doi.org/10.1016/j.applthermaleng.2010.08.021

(18) Bontemps, A., Ahmad, M., Johannès, K., Sallée, H. (2011). Experimental and modelling study of twin cells with latent heat storage walls. Energy and Buildings, 43(9): 2456-2461. https://doi.org/10.1016/j.enbuild.2011.05.030

(19) Guichard, S., Miranville, F., Bigot. D., Boyer. H. (2014). A thermal model for phase change materials in a building roof for a tropical and humid climate. Model description and elements of validation. Energy and Buildings, 70: 71-80. https://doi.org/10.1016/j.enbuild.2013.11.079

(20) Reddy, T. (2006). Literature review on calibration of building energy simulation programs: uses, problems, procedures, uncertainty and tools. ASHRAE Transactions, 112 (1): 226-240.

(21) Raftery, P., Keane, M., O'Donnell, J. (2011). Calibrating whole building energy models: An evidence-based methodology. Energy and Buildings, 43(9): 2356-2364. https://doi.org/10.1016/j.enbuild.2011.05.020

(22) De la Flor, F. J. S., Domínguez, S. A., Félix, J. L. M., Falcón, R. G. (2008). Climatic zoning and its application to Spanish building energy performance regulations. Energy & Buildings, 40(10): 1984-1990. https://doi.org/10.1016/j.enbuild.2008.05.006

(23) Ruiz Valero, Letzai (2013) Optimización y propuesta de sistema opaco de cerramiento multicapa ligero con estructura de light steel frame como alternativa competitiva a los sistemas de cerramientos tradicionales. PhD. Universidad Politécnica de Madrid.

(24) Cuerda, E., Pérez, M., Neila, J. (2014). Facade typologies as a tool for selecting refurbishment measures for the Spanish residential building. Energy and Buildings, 76: 119 –129. https://doi.org/10.1016/j.enbuild.2014.02.054

(25) Cuerdo-Vilches, T. (2014). Análisis de soluciones innovadoras para rehabilitación de fachada en vivienda social con Documentos de Idoneidad Técnica (DIT, DITE/ETE, ditplus). Paper presented at the 1st Congreso Internacional sobre Investigación en Construcción y Tecnología Arquitectónicas, Madrid.

(26) Alonso, C., Oteiza, I., García, J., Martín, F. (2016). Energy consumption to cool and heat experimental modules for the energy refurbishment of façades. Three case studies in Madrid. Energy and Buildings, 126: 252–262. https://doi.org/10.1016/j.enbuild.2016.04.034

(27) AEMET. http://www.aemet.es/es/serviciosclimaticos/datosclimatologicos/valoresclimatologicos?l=5783&k=and. (Accessed 10/07/2016)

Published

2017-12-30

How to Cite

Guerrero-Rubio, J., Sendra, J. J., Fernández-Agüera J., & Oteiza, I. (2017). Test cell data-based predictive modelling to determine HVAC energy consumption for three façade solutions in Madrid. Informes De La Construcción, 69(548), e225. https://doi.org/10.3989/id.54794

Issue

Section

Research Articles