Extraction systems as construction techniques to prevent the entry of radon gas in homes

Authors

  • B. Frutos Instituto de Ciencias de la Construcción Eduardo Torroja, CSIC
  • M. Olaya Instituto de Ciencias de la Construcción Eduardo Torroja, CSIC
  • J. L. Esteban Instituto de Ciencias de la Construcción Eduardo Torroja, CSIC

DOI:

https://doi.org/10.3989/ic.09.056

Keywords:

Radon, prevention of entry, mitigation actions, extraction solutions, Efficiency

Abstract


The health risk associated to high radon levels in living spaces leads to perform remedial actions in buildings with radon reduction techniques to reduce radon concentration down to acceptable levels. Within this type of solution, extraction systems, consisting in sumps buried in the ground and connected to the outside through pipes, have demonstrated a high effectiveness in reducing the flow of radon that penetrates into a building from the field. This article presents the results of effectiveness of 4 extraction solutions implemented in a module representative of a home, built in an area with high radon concentrations. Effectiveness is studied depending on the locations of the sumps, with centered or perimeter situation under the floor of the module, and with different types of expulsion of gas, natural convection or forced convection. The main conclusion include the high efficiency displayed by extraction system, with reduction ranges between 91% and 99%, with the exception of the system that use the sump buried by the outer perimeter of the module, and working by natural convection, which actually awarded only in the range of 53% to 58%.

Downloads

Download data is not yet available.

References

(1) IARC Monographs on the evaluation of carcinogenic risks to humans. Volume 43. Man-made mineral fibers and radon. World Health Organization- International Agency for Research on Cancer.1988.

(2) WHO handbook on indoor radon: a public health perspective. ISBN 978 92 4 154767 3. World Health Organization 2009.

(3) Darby S et al. Radon in homes and risk of lung cancer: collaborative analysis of individual data from 13 European case-control studies. BMJ. 2005 Jan 29; 330 (7485): 223. doi:10.1136/bmj.38308.477650.63 PMid:15613366    PMCid:546066

(4) Comisión de las Comunidades Europeas. Recomendación de la Comisión de 21-2-1990 relativa a la protección de la población contra peligros de una exposición al radón en el interior de edificios. (90/143/Euratom). D.O.C.E. L80, 2628.

(5) Real Decreto 314/2006, de 17 de marzo, por el que se aprueba el Código Técnico de la Edificación. BOE número 74 de 28/3/2006, páginas 11816 a 11831 (16 Págs.) www.codigotecnico.org.

(6) Ley 38/1999, de 5 de noviembre, de Ordenación de la Edificación. (BOE núm. 266, de 6-11-1999).

(7) Algunos documentos de interés en la bibliografía: • Bernard Collignan. Réduire la concentration en radon dans les bâtiments existants. Centre Scientifique et Technique de la Construction (CSTB) Francia 1999. • BRE Guide. Buildings and radon. ISBN: 1860810705. 1996. • C R Scivyer. Surveying dwellings with high indoor radon levels: a BRE guide to radon remedial measures in existing dwellings. ISBN: 851255825. 1993. • Clavensjön Bertil; Akertblom Gustav. The Radon Book. Measures against radon. The Swedish Council for Building Research. Suecia 1994. • Environmental Protection Agency (EPA). Building Radon Out. USA 2001.

(8) Berenguer Subils, Mª José. Notas Técnicas de Prevención. NTP 440: Radón en ambientes interiores. Ministerio de Trabajo y Asuntos Sociales. España.

(9) Quindós Poncela, L. S. Radón, un gas radiactivo de origen natural en su casa. Universidad de Cantabria. Consejo de Seguridad Nuclear. 1995. ISBN 84-8102-114-8.

(10) Neznal M. et al. The new method for assessing the radon risk of building sites.- Czech. Geol. Survey Special Papers, 47. p., CGS Prague. 2004.

(11) Font, Ll. and Baixeiras, C. “The RAGENA dynamic model of radon generation, entry and accumulation indoors” The Science of the Total Environment, Vol. 307 pp. 55-69. 2003. doi:10.1016/S0048-9697(02)00462-X

(12) Hintenlang D.E; Al-Ahmady K.K. Pressure differentials for radon entry coupled to periodic atmospheric pressure variations. Indoor Air, Volume 2, Number 4, pp. 208-215(8). December 1992.

(13) Yu K; Youg E; Li K. A study of factors affecting indoor radon properties. Health Phys. vol. 71 (2) 179-184. 1996. doi:10.1097/00004032-199608000-00008 PMid:8690600

(14) Ward D; Borak T; Gadd M. Characterization of 222Rn entry into a basement structure surrounded by low- permeability soil. Health Phys. vol. 65 (1) 1-11. 1993. doi:10.1097/00004032-199307000-00001 PMid:8505221

(15) Nazaroff WW; Moed BA; Sextro RG. Soil as a source of indoor radon: generation, migration, and entry. In: Nazaroff WW, Nero AV, editors. Radon and its decay products in indoor air. New York: Wiley-Interscience, p. 57-112. 1988.

(16) Renault P; Mohrath D; Gaudu J-C; Fumanal J-C. Air pressure fluctuations in a prairie soil. Soil Science Society of America journal, vol. 62, no. 3, pp. 553-563. 1998. doi:10.2136/sssaj1998.03615995006200030001x

(17) Allen L; Robinson Richard G; Sextro and William J. Riley. Soil-gas entry into houses driven by atmospheric pressure fluctuations-the influence of soil properties. Atmospheric Environment vol. 31, no. 10, pp. 1487-1495. 1997.

(18) Scivyer C R; Jaggs M P R. Dwellings with cellars and basements: a BRE guide to radon remedial measures in existing dwellings. ISBN: 1860812198. 1998.

Downloads

Published

2011-03-31

How to Cite

Frutos, B., Olaya, M., & Esteban, J. L. (2011). Extraction systems as construction techniques to prevent the entry of radon gas in homes. Informes De La Construcción, 63(521), 23–36. https://doi.org/10.3989/ic.09.056

Issue

Section

Research Articles