A comparative study of the methods to assess the thermal transmittance in opaque walls in the Mediterranean winter

Authors

DOI:

https://doi.org/10.3989/ic.62542

Keywords:

Thermal transmittance, UNE-EN ISO 6946, ISO 9869-1, quantitative infrared thermography method, Mediterranean, winter

Abstract


In Spain, most of the building stock has an inefficient energy performance. To change this situation, among other aspects, building envelopes must be analysed to change this situation. Thermal transmittance is one of the most significant properties related to building envelopes. However, in-situ evaluation methodologies for this property are designed for cold climates. On the other hand, theoretical methods have a high associated uncertainty. Therefore, it is necessary to study the application of these in situ methods in mild climates such as the Mediterranean one. This study analyses both theoretical and experimental methods. For this purpose, four case studies have been monitored during the winter. Results show that representative results could be obtained with adequate metrological conditions and stable environmental conditions.

Downloads

Download data is not yet available.

References

(1) Li, F. G. N. et al. (2014). Solid-wall U-values: heat flux measurements compared with standard assumptions. Building Research & Information, 43(2) 238-252. https://doi.org/10.1080/09613218.2014.967977

(2) Stevens, G. & Bradford, J. (2013). Do U-value insulation? England's field trial of solid wall insulation. eceee 2013 Summer Study, 1269-1280.

(3) Kurtz, F., Monzón, M. & López-Mesa, B. (2015). Energy and acoustics related obsolescence of social housing of Spain's post- war in less favoured urban areas. The case of Zaragoza. Informes de la Construcción, 67(Extra-1) m021. https://doi.org/10.3989/ic.14.062

(4) Rubel, F. & Kottek, M. (2010). Observed and projected climate shifts 1901-2100 depicted by world maps of the Köppen-Geiger climate classification. Meteorologische Zeitschrift, 19(2) 135-141. https://doi.org/10.1127/0941-2948/2010/0430

(5) Sánchez-García, D., Sánchez-Guevara, C. & Rubio-Bellido, C. (2016). Sevilla The adaptive approach to thermal comfort in Seville. Anales de Edificación, 2 38-48. https://doi.org/10.20868/ade.2016.3197

(6) AENOR. (2012). UNE-EN ISO 6946:2012. Componentes y elementos para la edificación. Resistencia térmica y transmitancia térmica. Método de cálculo. (ISO 6946:2007).

(7) International Organization for Standardization. (2014). ISO 9869-1:2014 - Thermal insulation - Building elements - In situ measurement of thermal resistance and thermal transmittance. Part 1: Heat flow meter method.

(8) Albatici, R. & Tonelli, A. M. (2010). Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site. Energy and Buildings, 42(11) 2177-2183. https://doi.org/10.1016/j.enbuild.2010.07.010

(9) Albatici, R., Tonelli, A. M. & Chiogna, M. (2015). A comprehensive experimental approach for the validation of quantitative infrared thermography in the evaluation of building thermal transmittance. Applied Energy, 141 218-228. https://doi.org/10.1016/j.apenergy.2014.12.035

(10) Dall'O', G., Sarto, L. & Panza, A. (2013). Infrared screening of residential buildings for energy audit purposes: Results of a field test. Energies, 6(8) 3859-3878. https://doi.org/10.3390/en6083859

(11) Desogus, G., Mura, S. & Ricciu, R. (2011). Comparing different approaches to in situ measurement of building components thermal resistance. Energy and Buildings, 43(10) 2613-2620. https://doi.org/10.1016/j.enbuild.2011.05.025

(12) AENOR. (2012). UNE-EN ISO 10456:2012. Materiales y productos para la edificación. Propiedades higrotérmicas. Valores tabulados de diseño y procedimientos para la determinación de los valores térmicos declarados y de diseño. (ISO 10456:2007).

(13) Instituto Eduardo Torroja de Ciencias de la Construcción. (2010). Catálogo de elementos constructivos del CTE.

(14) Clarke, J. A. & Yaneske, P. P. (2009). A rational approach to the harmonisation of the thermal properties of building materials. Building and Environment, 44(10) 2046-2055. https://doi.org/10.1016/j.buildenv.2009.02.008

(15) Domínguez-Muñoz, F., Anderson, B., Cejudo-López, J. M. & Carrillo-Andrés, A. (2010). Uncertainty in the thermal conductivity of insulation materials. Energy Build, 42 2159-2168. https://doi.org/10.1016/j.enbuild.2010.07.006

(16) Prada, A., Cappelletti, F., Baggio, P. & Gasparella, A. (2014). On the effect of material uncertainties in envelope heat transfer simulations. Energy and Buildings, 71 53-60. https://doi.org/10.1016/j.enbuild.2013.11.083

(17) Pérez-Bella, J. M., Domínguez-Hernández, J., Cano-Suñén, E., Del Coz-Díaz, J. J. & Álvarez Rabanal, F. P. (2015). A correction factor to approximate the design thermal conductivity of building materials. Application to Spanish façades. Energy and Buildings, 88 153-164. https://doi.org/10.1016/j.enbuild.2014.12.005

(18) Ficco, G., Iannetta, F., Ianniello, E., D'Ambrosio Alfano, F. R. & Dell'Isola, M. (2015). U-value in situ measurement for energy diagnosis of existing buildings. Energy and Buildings, 104 108-121. https://doi.org/10.1016/j.enbuild.2015.06.071

(19) Asdrubali, F., D'Alessandro, F., Baldinelli, G. & Bianchi, F. (2014). Evaluating in situ thermal transmittance of green buildings masonries: A case study. Case Studies in Construction Materials, 1 53-59. https://doi.org/10.1016/j.cscm.2014.04.004

(20) Rasooli, A., Itard, L. & Ferreira, C. I. (2016). A response factor-based method for the rapid in-situ determination of wall's thermal resistance in existing buildings. Energy and Buildings, 119 51-61. https://doi.org/10.1016/j.enbuild.2016.03.009

(21) Lorencio Pérez, S., Molina García, Á. & García Legaz-Quesada, I. (Universidad Politécnica de Cartagena. Escuela Técnica Superior de Ingeniería Industrial, 2014). Trabajo fin de máster. Análisis termoflujométrico en cerramientos para climas secos.

(22) Domingo de Miguel, J. (Universidad de Navarra. Escuela Técnica Superior de Arquitectura, 2012). Trabajo fin de máster. Evaluación del comportamiento térmico e higrotérmico de cerramientos de madera.

(23) Nardi, I., Paoletti, D., Ambrosini, D., De Rubeis, T. & Sfarra, S. (2016). U-value assessment by infrared thermography: A comparison of different calculation methods in a Guarded Hot Box. Energy and Buildings, 122 211-221. https://doi.org/10.1016/j.enbuild.2016.04.017

(24) Watanabe, K. (1965). Architectural Planning Fundamentals.

(25) Biddulph, P. et al. (2014). Inferring the thermal resistance and effective thermal mass of a wall using frequent temperature and heat flux measurements. Energy and Buildings, 78 10-16. https://doi.org/10.1016/j.enbuild.2014.04.004

(26) Gobierno de España. (1979). Real Decreto 2429/79, de 6 de julio, por el que se aprueba la Norma Básica de la Edificación NBE-CT-79, sobre Condiciones Térmicas en los Edificios.

(27) Gobierno de España. (2006). Real Decreto 314/2006, de 17 de marzo, por el que se aprueba el Código Técnico de la Edificación.

(28) Rico Delgado, F. & Marín García, D. (Universidad de Sevilla. Escuela Técnica Superior de Ingeniería de Edificación, 2009). Tesis. Modelo de diagnóstico por imágenes en edificación mediante la aplicación de tecnologías avanzadas.

Published

2019-06-30

How to Cite

Bienvenido-Huertas, D., Rodríguez-Álvaro, R., Moyano, J., Marín, D., & Rico, F. (2019). A comparative study of the methods to assess the thermal transmittance in opaque walls in the Mediterranean winter. Informes De La Construcción, 71(554), e288. https://doi.org/10.3989/ic.62542

Issue

Section

Research Articles